kentix.comUser-Manual • AlarmManager-BASIC/PRO• MultiSensors and KeyPad• Accessories
4.4. Configuration in 8 stepsNoStepCommentStartup1Connect the AlarmManager via LAN cable to the PC. The yellow LED on the LAN connector indicates a c
4.5. Visual and acoustic signalingAlarmManagerLED-POWER: Lights after connection to the power supplyLED-GSM: Flashes: Booked into GSM network, ready
4.6. Alarm zonesMultiSensors connected to the AlarmManager and also the inputs of Kentix IO-modules can be assigned to different alarm zones. With th
4.8. User accountsIn the user accounts the setup of the permissions and the alarming is done.Only if the required user data is entered, a user can co
4.9. SMS commands for remote control of AlarmManagerThe AlarmManager reports not only all the alarms via SMS, it can be also remotely controlled via
4.10.Settings - AlarmManager-BASIC and -PROGeneral SettingsSystem nameEnter the name of the system and choose the active state.Regional settingsThis
Network monitoringConfigure up to 100 network devices (BASIC: 3 devices). Network services of each device, which should be monitored, can be assigned
4.12.SMS gateway functionExternal applications such as Network monitoring systems can send via the AlarmManager-PRO SMS text messages via the integra
4.13.MIB for SNMP-SystemsFor the AlarmManager-PRO a MIB (Management Information Base) is available, which describes the information that can be reque
4.14.Execution of Firmware UpdatesWe are always looking to include innovations of development in our products and to ensure their faultless operation
1. Introduction and summary 4 1.1. Features 4
4.15.Connections - AlarmManager-BASIC/PROAccording to the two types of installation "Plug‘n Play" or "wired connection" you will
External I/Os AlarmManager-BASIC/PROExamples of the external circuit of the AlarmManager. Shows the internal 12-pin terminal of the AlarmManager. The
5. MultiSensorsThe MultiSensor-RF (ZigBee radio) and MultiSensor-LAN (network) mainly differ in the way of communication. Additionally the MultiSen
5.3. MultiSensor-RFThe MultiSensor-RF is configured by the ControlCenter. Updating the device is neither possible nor necessary.5.3.1. Kentix system
5.4. MultiSensor-LANIn contrast to the MultiSensor-RF with radio interface the MultiSensor-LAN can also be used stand-alone without an AlarmManager.
DashboardMultiSensor values and status: Display of the sensor measurements and alarm conditions. This display will be actualized all 5 seconds.- No
NavigationDashboard - Starting page with measurement table, control of the 2nd digital output, logbookLogin - User loginConfiguration - Basic configu
E-MailIf the MultiSensor should be able to send e-mails in the case of alarm to a configured user, it is necessary to set an e-mail server (SMTP or E
Sensor-VibrationAlarm settings for the sensitivity of the internal vibration sensor. The sensitivity can be adjusted in 3 levels.If necessary the vib
5.4.7. SystemSystem informationShows the Firmware version number of the MultiSensor-LAN.The actual firmware can be found on the Kentix Website in the
5.6.1. Safety note and installation 35
5.5.MultiSensor-Door / MultiSensor-RACK-MINIThe MultiSensor-Door / -RACK-MINI is designed for an efficient intrusion detection on doors or windows or
5.5.1. Mounting instructionsThe MultiSensor-Door / -RACK-MINI is equipped with several different sensors. To ensure the best evaluation and functioni
5.5.2. Usage of the reed contactThe reed contact extends the MultiSensor-Door / -RACK-MINI by an additional alarm contact for the definite open/close
5.5.3. Opening of the casing / replacement of batteryThe board of the MultiSensor-Door / -RACK-MINI is fixed in the lid of the casing which is connec
5.5.6. Profile descriptionThe MultiSensor-Door / -RACK-MINI is configured for its intended use with the help of so called door-profiles and an associ
5.6. MultiSensor-RackThe MultiSensor-RACK can be operated as stand alone device, but also in combination with an AlarmManager-PRO. The AlarmManager t
5.6.3. Overview connectionsNetwork-PortKentix System-jack 1Kentix System-jack 2OLED DisplayDisplay scroll forward Display scroll backSystem stateR
5.6.4. Recommended installation5.6.5. ConfigurationConfigurationIn the following the stand alone functionality of the integrated web servers is desc
5.6.6. EnergySensor - EnergyShows all actual energy measurement values for PDU 1+2 (PDU=Power Distribution Unit), the energy consumption with costs a
Active powerThe active power (P) shows the actual power of the PDU. Its calculated by multiplying voltage, current and the power factor.Apparent powe
1. Introduction and summaryThank you for your decision to buy a KENTIX monitoring solution based on the KENTIX MultiSensor technology.1.1. FeaturesTh
5.6.7. EnergySensor - MonitoringGraphical display of the recorded active power and energy consumption and costs.The recording is stored for up to 1 y
5.6.8. ControlSwitch alarm output 2 Changes the state of the 2nd alarm output (output 1 is controlled by the alarming) for the entered switching tim
5.6.9. Configuration - EnergySensorWith the following settings set the limits for the alarm triggering of the energy sensors. If an alarm is triggere
Alarm handlingThe Retrigger time defines, after which time the alarms Flicker, Swell or Peak are reset for the next triggering. This setting avoids t
5.6.12. Configuration of the vibration sensorDefine the triggering threshold for the integrated vibration sensor. The alarm is triggered, when the th
5.7. Control a network camera with MultiSensor-LAN/RACKThe MultiSensor-RACK offers the possibility to send a control sequence as a HTTP request to an
5.9. Perform software update on MultiSensor-LAN/RACKThe MultiSensor-LAN/RACK offers the possibility to actualize its software via the integrated web
6. How to open the AlarmManager chassis for inserting a SIM cardThe device lids of the AlarmManager are jammed in one surrounding on the device botto
7. KeyPadThe KeyPad is used for arm-disarm switching of the AlarmManager on the ground. The KeyPad is just like the MultiSensors integrated into the
7.1.Operation KeyPadFirst press the desired function key (arm, disarm, zone) and then enter your personal 4-digit code. The function is triggered imm
2. Connection examples and installation notes2.1. CompleteSet 12.2. CompleteSet 2 "1. Connect AlarmManager and MultiSensor via Modular cable.2
8. Enhancements8.1. Leakage sensor (KLS03)The leakage sensor KLS03 is shipped with a 10m patch cable for a direct connection to Kentix devices via th
Connection example 2: Daisy chaining leakage sensorsIt is possible to to chain up to 5 leakage sensors together and connect them to a Kentix system j
8.2. Kentix Power-Adapter (KIO1) with digital input clipsThe Kentix I/O Power-Adapter is used to expand your Kentix-solution to include the additiona
8.3. Kentix Power-Adapter (KIO2) for powering a MultiSensorThe Kentix I/O Power-Adapter KIO2 is used to expand your Kentix solution by offering the f
8.4. Kentix Power-Adapter (KIO3) with digital I/O clipsThe Kentix I/O Power-Adapter is used to expand your Kentix-solution to include the additional
8.5. Overview and Application examples for Power-Adapters (KIO1-3)##ImageDescriptionApplication examplesPower-Adapter with digital I/O clips Adapter
8.6. Kentix Alarm sirene (KFLASH1)The Kentix Alarm sirene can be used for an acoustical and optical signalization in case of an alarm.#It is suitable
8.6.1. ConfigurationTo trigger the Alarm sirene relay times have to be configured in the AlarmManager or the MultiSensor.For the AlarmManager and all
8.7. Kentix IO-ModulesThe AlarmManager-PRO can be extended by additional digital Inputs and Outputs via special Expansion modules. For this 2 externa
8.8. MultiSensor-LAN-RF (LAN-ZigBee Repeater)The MultiSensor-LAN-RF offers the same functionality as the MultiSensor-LAN.Moreover it allows the creat
2.3. CompleteSet with optional equipment1. MultiSensor-LAN:#Establish network connection and external power supply, if needed.#Connect to the sensor
9. Kentix AlarmManager Smartphone-AppWith the Kentix-App a monitoring and control of a Kentix System via iPhone / iPad or Android devices is possible
9.3. SMS ControlWhen the AlarmManager cannot be accessed via the local network, it can be switched via SMS commands. Trying to access without network
10. Data sheets10.1.Data sheet AlarmManager-BASIC/PRO (KAM-BASIC/PRO)Number of MultiSensor (KAM-BASIC)Number of MultiSensor (KAM-PRO)Max 10 pc MultiS
10.2.Data sheet MultiSensor-RF (KMS-RF)Connectable devicesAlarmManager-BASIC (KAM-BASIC)AlarmManager-PRO (KAM-PRO)Sensor - temperaturerange -20 to 99
10.3.Data sheet MultiSensor-LAN (KMS-LAN)Connectable devicesStand-Alone operation (integrated web server)AlarmManager-PROSensor - temperaturerange -2
10.4.Data sheet MultiSensor-LAN-RF (KMS-LAN-RF)Connectable devicesStand-Alone operation (integrated web server)AlarmManager-PROSensor - temperaturera
10.5.Data sheet MultiSensor-RACK (KMS-RACK)Connectable devicesStand-Alone operation (Integrated Web-Server)AlarmManager-PROSensor - temperaturerange
10.6.Data sheet MultiSensor-Door (KMS-Door)Connectable devicesAlarmManager-BASIC (KAM-BASIC)AlarmManager-PRO (KAM-PRO)Sensor - temperaturerange -20 t
10.7.Data sheet MultiSensor-RACK-MINI (KMS-RACK-MINI)Connectable devicesAlarmManager-BASIC (KAM-BASIC)AlarmManager-PRO (KAM-PRO)Sensor - temperaturer
10.8.Data sheet KeyPad (KKP)Connectable devicesAlarmManager-BASIC/PROMultiSensor-LAN-RFBuzzer70dB, 2.3kHzLEDZone (RED/GREEN)Arm (RED/GREEN)Disarm (RE
2.4. Alarm-inputsWhen installing the device follow the instructions in this manual. Please note polarity and technical data of the inputs.2.5. Relay
10.9.Data sheet digital I/O expansion-module (KIO7052)DescriptionExpansion module for connection to the AlarmManager-PRO. This module extends the ext
10.10.Data sheet digital I/O expansion-module (KIO7053)###############DescriptionExpansion module for connection to the AlarmManager-PRO. This module
10.11.Data sheet leakage sensor (KLS03)ConnectivityAlarmManager-BASIC (KAM-BASIC)AlarmManager-PRO (KAM-PRO)MultiSensor-RF (KMS-RF)MultiSensor-LAN (KM
11. Checklist - Acceptance reportAfter the successful installation, we implicitly recommend to do a function-check of all components, to ensure the c
Acceptance report - AlarmManager-BASIC/PRO###Date Customer#### Technical service"DeviceFunctionAlarmManager BASIC+PROactual s
Acceptance report - MultiSensors / KeyPads / Leakage-sensor##Date Customer#### Technical service"DevicePlace of installationF
12. SupportFor technical questions about the products please contact our support team by e-mail.Send an e-mail with your questions and all the import
✓The AlarmManager is the central unit.#With the BASIC-Version up to 10 MultiSensors and 3 KeyPad wall-mount keyboards#can be connected. The PRO-Versio
4. AlarmManager-BASIC/PRO4.1. Login to the AlarmManagerThe PC-Client Kentix ControlCenter displays a Login-screen after starting the Application.To l