Page 2

4.4. Configuration in 8 stepsNoStepCommentStartup1Connect the AlarmManager via LAN cable to the PC. The yellow LED on the LAN connector indicates a c

Page 3

4.5. Visual and acoustic signalingAlarmManagerLED-POWER: Lights after connection to the power supplyLED-GSM: Flashes: Booked into GSM network, ready

Page 4 - 1. Introduction and summary

4.6. Alarm zonesMultiSensors connected to the AlarmManager and also the inputs of Kentix IO-modules can be assigned to different alarm zones. With th

Page 5 - 2.2. CompleteSet 2

4.8. User accountsIn the user accounts the setup of the permissions and the alarming is done.Only if the required user data is entered, a user can co

Page 6 - KMS-Door

4.9. SMS commands for remote control of AlarmManagerThe AlarmManager reports not only all the alarms via SMS, it can be also remotely controlled via

Page 7 - 2.6. Power supply

4.10.Settings - AlarmManager-BASIC and -PROGeneral SettingsSystem nameEnter the name of the system and choose the active state.Regional settingsThis

Page 8 - KENTIX system-components

Network monitoringConfigure up to 100 network devices (BASIC: 3 devices). Network services of each device, which should be monitored, can be assigned

Page 9 - 4. AlarmManager-BASIC/PRO

4.12.SMS gateway functionExternal applications such as Network monitoring systems can send via the AlarmManager-PRO SMS text messages via the integra

Page 10 - 4.4. Configuration in 8 steps

4.13.MIB for SNMP-SystemsFor the AlarmManager-PRO a MIB (Management Information Base) is available, which describes the information that can be reque

Page 11

4.14.Execution of Firmware UpdatesWe are always looking to include innovations of development in our products and to ensure their faultless operation

Page 12 - 4.7.Quitting Alarms

1. Introduction and summary 4 1.1. Features 4

Page 13 - 4.8. User accounts

4.15.Connections - AlarmManager-BASIC/PROAccording to the two types of installation "Plug‘n Play" or "wired connection" you will

Page 14 - SMS answer

External I/Os AlarmManager-BASIC/PROExamples of the external circuit of the AlarmManager. Shows the internal 12-pin terminal of the AlarmManager. The

Page 15 - General Settings

5. MultiSensorsThe MultiSensor-RF (ZigBee radio) and MultiSensor-LAN (network) mainly differ in the way of communication. Additionally the MultiSen

Page 16 - SMS alarm forwarding

5.3. MultiSensor-RFThe MultiSensor-RF is configured by the ControlCenter. Updating the device is neither possible nor necessary.5.3.1. Kentix system

Page 17 - 4.12.SMS gateway function

5.4. MultiSensor-LANIn contrast to the MultiSensor-RF with radio interface the MultiSensor-LAN can also be used stand-alone without an AlarmManager.

Page 18 - 4.13.MIB for SNMP-Systems

DashboardMultiSensor values and status: Display of the sensor measurements and alarm conditions. This display will be actualized all 5 seconds.- No

Page 19

NavigationDashboard - Starting page with measurement table, control of the 2nd digital output, logbookLogin - User loginConfiguration - Basic configu

Page 20

E-MailIf the MultiSensor should be able to send e-mails in the case of alarm to a configured user, it is necessary to set an e-mail server (SMTP or E

Page 21

Sensor-VibrationAlarm settings for the sensitivity of the internal vibration sensor. The sensitivity can be adjusted in 3 levels.If necessary the vib

Page 22 - 5. MultiSensors

5.4.7. SystemSystem informationShows the Firmware version number of the MultiSensor-LAN.The actual firmware can be found on the Kentix Website in the

Page 23 - 5.3. MultiSensor-RF

5.6.1. Safety note and installation 35

Page 24 - 5.4. MultiSensor-LAN

5.5.MultiSensor-Door / MultiSensor-RACK-MINIThe MultiSensor-Door / -RACK-MINI is designed for an efficient intrusion detection on doors or windows or

Page 25 - Dashboard

5.5.1. Mounting instructionsThe MultiSensor-Door / -RACK-MINI is equipped with several different sensors. To ensure the best evaluation and functioni

Page 26

5.5.2. Usage of the reed contactThe reed contact extends the MultiSensor-Door / -RACK-MINI by an additional alarm contact for the definite open/close

Page 27

5.5.3. Opening of the casing / replacement of batteryThe board of the MultiSensor-Door / -RACK-MINI is fixed in the lid of the casing which is connec

Page 28 - 5.4.6. Users

5.5.6. Profile descriptionThe MultiSensor-Door / -RACK-MINI is configured for its intended use with the help of so called door-profiles and an associ

Page 29 - 5.4.8. Switch alarm output 2

5.6. MultiSensor-RackThe MultiSensor-RACK can be operated as stand alone device, but also in combination with an AlarmManager-PRO. The AlarmManager t

Page 30

5.6.3. Overview connectionsNetwork-PortKentix System-jack 1Kentix System-jack 2OLED DisplayDisplay scroll forward Display scroll backSystem stateR

Page 31

5.6.4. Recommended installation5.6.5. ConfigurationConfigurationIn the following the stand alone functionality of the integrated web servers is desc

Page 32

5.6.6. EnergySensor - EnergyShows all actual energy measurement values for PDU 1+2 (PDU=Power Distribution Unit), the energy consumption with costs a

Page 33

Active powerThe active power (P) shows the actual power of the PDU. Its calculated by multiplying voltage, current and the power factor.Apparent powe

Page 34 - 5.5.7. Testing the settings

1. Introduction and summaryThank you for your decision to buy a KENTIX monitoring solution based on the KENTIX MultiSensor technology.1.1. FeaturesTh

Page 35 - 5.6. MultiSensor-Rack

5.6.7. EnergySensor - MonitoringGraphical display of the recorded active power and energy consumption and costs.The recording is stored for up to 1 y

Page 36 - 5.6.3. Overview connections

5.6.8. ControlSwitch alarm output 2 Changes the state of the 2nd alarm output (output 1 is controlled by the alarming) for the entered switching tim

Page 37 - Configuration

5.6.9. Configuration - EnergySensorWith the following settings set the limits for the alarm triggering of the energy sensors. If an alarm is triggere

Page 38 - 5.6.6. EnergySensor - Energy

Alarm handlingThe Retrigger time defines, after which time the alarms Flicker, Swell or Peak are reset for the next triggering. This setting avoids t

Page 39

5.6.12. Configuration of the vibration sensorDefine the triggering threshold for the integrated vibration sensor. The alarm is triggered, when the th

Page 40

5.7. Control a network camera with MultiSensor-LAN/RACKThe MultiSensor-RACK offers the possibility to send a control sequence as a HTTP request to an

Page 41 - 5.6.8. Control

5.9. Perform software update on MultiSensor-LAN/RACKThe MultiSensor-LAN/RACK offers the possibility to actualize its software via the integrated web

Page 42

6. How to open the AlarmManager chassis for inserting a SIM cardThe device lids of the AlarmManager are jammed in one surrounding on the device botto

Page 43 - 5.6.11. System

7. KeyPadThe KeyPad is used for arm-disarm switching of the AlarmManager on the ground. The KeyPad is just like the MultiSensors integrated into the

Page 44 - KENTIX system jack

7.1.Operation KeyPadFirst press the desired function key (arm, disarm, zone) and then enter your personal 4-digit code. The function is triggered imm

Page 45

2. Connection examples and installation notes2.1. CompleteSet 12.2. CompleteSet 2 "1. Connect AlarmManager and MultiSensor via Modular cable.2

Page 46

8. Enhancements8.1. Leakage sensor (KLS03)The leakage sensor KLS03 is shipped with a 10m patch cable for a direct connection to Kentix devices via th

Page 47

Connection example 2: Daisy chaining leakage sensorsIt is possible to to chain up to 5 leakage sensors together and connect them to a Kentix system j

Page 48 - 7. KeyPad

8.2. Kentix Power-Adapter (KIO1) with digital input clipsThe Kentix I/O Power-Adapter is used to expand your Kentix-solution to include the additiona

Page 49 - 7.1.Operation KeyPad

8.3. Kentix Power-Adapter (KIO2) for powering a MultiSensorThe Kentix I/O Power-Adapter KIO2 is used to expand your Kentix solution by offering the f

Page 50 - 8. Enhancements

8.4. Kentix Power-Adapter (KIO3) with digital I/O clipsThe Kentix I/O Power-Adapter is used to expand your Kentix-solution to include the additional

Page 51

8.5. Overview and Application examples for Power-Adapters (KIO1-3)##ImageDescriptionApplication examplesPower-Adapter with digital I/O clips Adapter

Page 52

8.6. Kentix Alarm sirene (KFLASH1)The Kentix Alarm sirene can be used for an acoustical and optical signalization in case of an alarm.#It is suitable

Page 53

8.6.1. ConfigurationTo trigger the Alarm sirene relay times have to be configured in the AlarmManager or the MultiSensor.For the AlarmManager and all

Page 54

8.7. Kentix IO-ModulesThe AlarmManager-PRO can be extended by additional digital Inputs and Outputs via special Expansion modules. For this 2 externa

Page 55 - Application examples

8.8. MultiSensor-LAN-RF (LAN-ZigBee Repeater)The MultiSensor-LAN-RF offers the same functionality as the MultiSensor-LAN.Moreover it allows the creat

Page 56 - Alarm sirene

2.3. CompleteSet with optional equipment1. MultiSensor-LAN:#Establish network connection and external power supply, if needed.#Connect to the sensor

Page 57 - 8.6.1. Configuration

9. Kentix AlarmManager Smartphone-AppWith the Kentix-App a monitoring and control of a Kentix System via iPhone / iPad or Android devices is possible

Page 58 - 8.7. Kentix IO-Modules

9.3. SMS ControlWhen the AlarmManager cannot be accessed via the local network, it can be switched via SMS commands. Trying to access without network

Page 59

10. Data sheets10.1.Data sheet AlarmManager-BASIC/PRO (KAM-BASIC/PRO)Number of MultiSensor (KAM-BASIC)Number of MultiSensor (KAM-PRO)Max 10 pc MultiS

Page 60 - 9.2. AlarmManager

10.2.Data sheet MultiSensor-RF (KMS-RF)Connectable devicesAlarmManager-BASIC (KAM-BASIC)AlarmManager-PRO (KAM-PRO)Sensor - temperaturerange -20 to 99

Page 61 - 9.3. SMS Control

10.3.Data sheet MultiSensor-LAN (KMS-LAN)Connectable devicesStand-Alone operation (integrated web server)AlarmManager-PROSensor - temperaturerange -2

Page 62 - 10. Data sheets

10.4.Data sheet MultiSensor-LAN-RF (KMS-LAN-RF)Connectable devicesStand-Alone operation (integrated web server)AlarmManager-PROSensor - temperaturera

Page 63

10.5.Data sheet MultiSensor-RACK (KMS-RACK)Connectable devicesStand-Alone operation (Integrated Web-Server)AlarmManager-PROSensor - temperaturerange

Page 64

10.6.Data sheet MultiSensor-Door (KMS-Door)Connectable devicesAlarmManager-BASIC (KAM-BASIC)AlarmManager-PRO (KAM-PRO)Sensor - temperaturerange -20 t

Page 65

10.7.Data sheet MultiSensor-RACK-MINI (KMS-RACK-MINI)Connectable devicesAlarmManager-BASIC (KAM-BASIC)AlarmManager-PRO (KAM-PRO)Sensor - temperaturer

Page 66

10.8.Data sheet KeyPad (KKP)Connectable devicesAlarmManager-BASIC/PROMultiSensor-LAN-RFBuzzer70dB, 2.3kHzLEDZone (RED/GREEN)Arm (RED/GREEN)Disarm (RE

Page 67

2.4. Alarm-inputsWhen installing the device follow the instructions in this manual. Please note polarity and technical data of the inputs.2.5. Relay

Page 68

10.9.Data sheet digital I/O expansion-module (KIO7052)DescriptionExpansion module for connection to the AlarmManager-PRO. This module extends the ext

Page 69 - 10.8.Data sheet KeyPad (KKP)

10.10.Data sheet digital I/O expansion-module (KIO7053)###############DescriptionExpansion module for connection to the AlarmManager-PRO. This module

Page 70

10.11.Data sheet leakage sensor (KLS03)ConnectivityAlarmManager-BASIC (KAM-BASIC)AlarmManager-PRO (KAM-PRO)MultiSensor-RF (KMS-RF)MultiSensor-LAN (KM

Page 71

11. Checklist - Acceptance reportAfter the successful installation, we implicitly recommend to do a function-check of all components, to ensure the c

Page 72

Acceptance report - AlarmManager-BASIC/PRO###Date Customer#### Technical service"DeviceFunctionAlarmManager BASIC+PROactual s

Page 73

Acceptance report - MultiSensors / KeyPads / Leakage-sensor##Date Customer#### Technical service"DevicePlace of installationF

Page 74 - Function

12. SupportFor technical questions about the products please contact our support team by e-mail.Send an e-mail with your questions and all the import

Page 75 - Place of installation

✓The AlarmManager is the central unit.#With the BASIC-Version up to 10 MultiSensors and 3 KeyPad wall-mount keyboards#can be connected. The PRO-Versio

Page 76 - 12. Support

4. AlarmManager-BASIC/PRO4.1. Login to the AlarmManagerThe PC-Client Kentix ControlCenter displays a Login-screen after starting the Application.To l

Commentaires sur ces manuels

Pas de commentaire