Kentix KSS-BASIC-2-B Manuel de service Page 32

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 76
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 31
5.5.2. Usage of the reed contact
The reed contact extends the MultiSensor-Door / -RACK-MINI by an additional alarm contact for the definite
open/closed detection of a door or window. The contact reacts to magnetic fields (magnet contained in
package). For the installation a wiring is not necessary.
To ensure the functionality of the contact, take care to not exceed the maximum distance of one
centimeter between magnet and casing and orientated to one side of the casing of the MultiSensor.
Depending on the type of the door or window it might be necessary to place a spacer between surface and
magnet to not exceed the maximum distance to the sensor.
Page (04-2015, subject to change) kentix.com32
Vue de la page 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 75 76

Commentaires sur ces manuels

Pas de commentaire