Page 1 - User-Manual

kentix.deUser-Manual • AlarmManager-BASIC/PRO• MultiSensors and KeyPad• Accessories

Page 2 - Content

Configuration in 8 stepsTo make an initial setup with the ControlCenter only the three register-tabs "Base-Settings - User Accounts - Sensor-Devi

Page 3

Visual and acoustic signaling!!!AlarmManagerLED-POWER:! ! Lights after connection to the power supplyLED-GSM:! ! Flashes: Booked into GSM network, rea

Page 4 - Introduction and summary

Alarm zonesMultiSensors connected to the AlarmManager and also the inputs of Kentix IO-modules can be assigned to different alarm zones. With this opt

Page 5 - CompleteSet 2

User accountsIn the user accounts the setup of the permissions and the alarming is done.Only if the required user data is entered, a user can control

Page 6 - KMS-Door

SMS commands for remote control of AlarmManagerThe AlarmManager reports not only all the alarms via SMS, it can be also remotely controlled via simple

Page 7 - Power supply

Advanced settings - AlarmManager-BASIC and -PROIn the advanced settings, additional functions of the AlarmManager can be activated.General SettingsBac

Page 8 - KENTIX system-components

Advanced settings - AlarmManager-PRO onlyNetwork CamerasThe AlarmManager-PRO can control cameras in its network to start the recording of a video or p

Page 9 - AlarmManager-BASIC/PRO

MIB for SNMP-SystemsFor the AlarmManager-PRO a MIB (Management Information Base) is available, which describes the information that can be requested o

Page 10 - Configuration in 8 steps

Execution of Firmware UpdatesWe are always looking to include innovations of development in our products and to ensure their faultless operation. Ther

Page 11 - Visual and acoustic signaling

Connections - AlarmManager-BASIC/PROAccording to the two types of installation "Plug‘n Play" or "wired connection" you will find a

Page 12 - Quitting Alarms

Content1. Introduction and summary! 41.1. Features! 41.2. Applications! 41.3. Safety note! 42. Connection examples and installation notes! 52.1. Comp

Page 13 - User accounts

External I/Os AlarmManager-BASIC/PROExamples of the external circuit of the AlarmManager. Shows the internal 12-pin terminal of the AlarmManager. The

Page 14 - SMS answer

License ManagementIn contrast to the AlarmManager-BASIC, the PRO-version contains additional useful features like e.g. connecting network-enabled Mult

Page 15 - Server Monitoring

MultiSensorsAccording to the two types of installation "Plug‘n Play" or "wired connection" you can find all connections of the Mu

Page 16 - External Alarms

External I/Os of MultiSensorsExamples of external circuits of the MultiSensors. This shows the internal 8-pin terminal of the MultiSensor. The interna

Page 17 - MIB for SNMP-Systems

MultiSensor-RFIt is not necessary to configure the MultiSensor-RF. Updating it is also not necessary/possible.For the setup of a MultiSensor-RF follow

Page 18 - Execution of Firmware Updates

MultiSensor-LANIn contrast to the MultiSensor-RF with radio interface the MultiSensor-LAN can also be used stand-alone without an AlarmManager. For co

Page 19

Software function MultiSensor-LANIn the following, the stand-alone functionality of the integrated web server is described. For the described function

Page 20 - Description - Relay-Contacts:

NavigationDashboard! ! - Starting page with measurement table, control of the 2nd digital output, logbookLogin! ! ! - User loginConfiguration! ! - Bas

Page 21 - License Management

E-MailIf the MultiSensor should be able to send e-mails in the case of alarm to a configured user, it is necessary to set an e-mail server (SMTP or ES

Page 22 - MultiSensors

Sensor-VibrationAlarm settings for the sensitivity of the internal vibration sensor. The sensitivity can be adjusted in 3 levels.If necessary the vibr

Page 23 - External I/Os of MultiSensors

5.7.3. Opening of the casing / replacement of battery! 345.7.4. Adding a MultiSensor-Door / -RACK-MINI! 345.7.5. Identifying a MultiSensor-Door / -RAC

Page 24 - MultiSensor-RF

SystemSystem informationShows the Firmware version number of the MultiSensor-LAN.The actual firmware can be found on the Kentix Website in the section

Page 25 - MultiSensor-LAN

MultiSensor-Door / MultiSensor-RACK-MINIThe MultiSensor-Door / -RACK-MINI is designed for an efficient intrusion detection on doors or windows or for

Page 26 - Dashboard

Mounting instructionsThe MultiSensor-Door / -RACK-MINI is equipped with several different sensors. To ensure the best evaluation and functioning of th

Page 27

Usage of the reed contactThe reed contact extends the MultiSensor-Door / -RACK-MINI by an additional alarm contact for the definite open/closed detect

Page 28

Opening of the casing / replacement of batteryThe board of the MultiSensor-Door / -RACK-MINI is fixed in the lid of the casing which is connected to t

Page 29

Profile descriptionThe MultiSensor-Door / -RACK-MINI is configured for its intended use with the help of so called door-profiles and an associated sen

Page 30 - Switch alarm output 2

MultiSensor-RackThe MultiSensor-RACK can be operated as stand alone device, but also in combination with an AlarmManager-PRO. The AlarmManager then co

Page 31

Overview connectionsNetwork-PortKentix System-jack 1Kentix System-jack 2OLED DisplayDisplay scroll forward Display scroll backSystem stateReset-Button

Page 32 - CORRECT WRONG

1. If possible, install the MultiSensor-RACK at the top position in the rack and leave 1 height unit free below the device.This ensures that the envir

Page 33 - Usage of the reed contact

EnergySensor - EnergyShows all actual energy measurement values for PDU 1+2 (PDU=Power Distribution Unit), the energy consumption with costs and the a

Page 34

Introduction and summaryThank you for your decision to buy a KENTIX monitoring solution based on the KENTIX MultiSensor technology.FeaturesThe KENTIX

Page 35 - Testing the settings

Active powerThe active power (P) shows the actual power of the PDU. Its calculated by multiplying voltage, current and the power factor.Apparent power

Page 36 - MultiSensor-Rack

EnergySensor - MonitoringGraphical display of the recorded active power and energy consumption and costs.The recording is stored for up to 1 year. If

Page 37 - Recommended installation

ControlSwitch alarm output 2 Changes the state of the 2nd alarm output (output 1 is controlled by the alarming) for the entered switching time. If „0“

Page 38 - Configuration

Configuration - EnergySensorWith the following settings set the limits for the alarm triggering of the energy sensors. If an alarm is triggered, e-mai

Page 39 - EnergySensor - Energy

Alarm handlingThe Retrigger time defines, after which time the alarms Flicker, Swell or Peak are reset for the next triggering. This setting avoids th

Page 40

Configuration of the vibration sensorDefine the triggering threshold for the integrated vibration sensor. The alarm is triggered, when the threshold i

Page 41 - EnergySensor - Monitoring

Control a network camera with MultiSensor-LAN/RACKThe MultiSensor-RACK offers the possibility to send a control sequence as a HTTP request to any IP r

Page 42

Perform software updates on MultiSensor-LAN/RACKThe MultiSensor-LAN/RACK offers the possibility to actualize its software via the integrated FTP-serve

Page 43 - Configuration - EnergySensor

How to open the case of MultiSensor and AlarmManagerThe device lids of the MultiSensor-RF/LAN or AlarmManager are jammed in one surrounding groove on

Page 44

KeyPadThe KeyPad is used for arm-disarm switching of the AlarmManager on the ground. The KeyPad is just like the MultiSensors integrated into the Zig

Page 45 - Kentix system jack

Connection examples and installation notesCompleteSet 11. Connect AlarmManager and MultiSensor via Modular cable.2. Connect power supply to AlarmManag

Page 46

Operation KeyPadFirst press the desired function key (arm, disarm, zone) and then enter your personal 4-digit code. The function is triggered immediat

Page 47

EnhancementsWith the Alarm inputs at the terminal blocks or the system jacks of AlarmManager and MultiSensor it is possible to connect external compon

Page 48

Connection example 2: Leakage-sensor connected to MultiSensorPlug the connection cable of the leakage-sensor into one of the jacks of the Kentix Power

Page 49 - Adding a KeyPad

Kentix Power-Adapter (KIO1)The Kentix I/O Power-Adapter is used to expand your Kentix-solution to include additional components.With the Adapter it‘s

Page 50 - Operation KeyPad

Kentix IO-ModulesThe AlarmManager-PRO can be extended by additional digital Inputs and Outputs via special Expansion modules. For this 2 external modu

Page 51 - Enhancements

MultiSensor-LAN-RF (LAN-ZigBee Repeater)The MultiSensor-LAN-RF offers the same functionality as the MultiSensor-LAN.Moreover it allows the creation of

Page 52 - Leakage-Sensor

Kentix AlarmManager Smartphone-AppWith the Kentix-App a monitoring and control of a Kentix System via iPhone / iPad or Android devices is possible. In

Page 53 - Kentix Power-Adapter (KIO1)

SMS ControlWhen the AlarmManager cannot be accessed via the local network, it can be switched via SMS commands. Trying to access without network conne

Page 54 - Kentix IO-Modules

Data sheets Data sheet AlarmManager-BASIC/PRO (KAM-BASIC/PRO)Number of MultiSensor (KAM-BASIC)Number of MultiSensor (KAM-PRO)Max 10 pc MultiSensor-RFM

Page 55

Data sheet MultiSensor-RF (KMS-RF)Connectable devicesAlarmManager-BASIC (KAM-BASIC)AlarmManager-PRO (KAM-PRO)Sensor - temperaturerange -20 to 99°C /

Page 56 - AlarmManager

CompleteSet with optional equipmentKMS-Door1. MultiSensor-LAN:Establish network connection and external power supply, if needed.Connect to the sensor

Page 57 - SMS Control

Data sheet MultiSensor-LAN (KMS-LAN)Connectable devicesStand-Alone operation (integrated web server)AlarmManager-PROSensor - temperaturerange -20 to

Page 58 - Data sheets

Data sheet MultiSensor-LAN-RF (KMS-LAN-RF)Connectable devicesStand-Alone operation (integrated web server)AlarmManager-PROSensor - temperaturerange -

Page 59

Data sheet MultiSensor-RACK (KMS-RACK)Connectable devicesStand-Alone operation (Integrated Web-Server)AlarmManager-PROSensor - temperaturerange -20 t

Page 60

Data sheet MultiSensor-Door (KMS-Door)Connectable devicesAlarmManager-BASIC (KAM-BASIC)AlarmManager-PRO (KAM-PRO)Sensor - temperaturerange -20 to 99°C

Page 61

Data sheet MultiSensor-RACK-MINI (KMS-RACK-MINI)Connectable devicesAlarmManager-BASIC (KAM-BASIC)AlarmManager-PRO (KAM-PRO)Sensor - temperaturerange -

Page 62

Data sheet KeyPad (KKP)Connectable devicesAlarmManager-BASIC/PROMultiSensor-LAN-RFBuzzer70dB, 2.3kHzLEDZone (RED/GREEN)Arm (RED/GREEN)Disarm (RED/GREE

Page 63

Data sheet digital I/O expansion-module (KIO7052)Page 66 ! ! ! ! (08-2014, subject to change)

Page 64

Data sheet digital I/O expansion-module (KIO7053)Page 67 ! ! ! ! (08-2014, subject to change)

Page 65 - Data sheet KeyPad (KKP)

Checklist - Acceptance reportAfter the successful installation, we implicitly recommend to do a function-check of all components, to ensure the clean

Page 66

Acceptance report - AlarmManager-BASIC/PRODeviceFunctionAlarmManager BASIC+PROactual software-/firmware version - check www.kentix.de or in the Kentix

Page 67

Alarm-inputsWhen installing the device follow the instructions in this manual. Please note polarity and technical data of the inputs.Relay contactsWhe

Page 68 - Checklist - Acceptance report

Acceptance report - MultiSensors / KeyPads / Leakage-sensorDevicePlace of installationFunctionKeypad #1Test arm/disarmKeypad #2Test arm/disarmKeypad #

Page 69 - Function

SupportFor technical questions about the products please contact our support team by e-mail.Send an e-mail with your questions and all the important

Page 70 - Place of installation

✓The AlarmManager is the central unit.With the BASIC-Version up to 10 MultiSensors and 3 KeyPad wall-mount keyboardscan be connected. The PRO-Version